AY2G-220W Custom Aluminum Heat Sink Housing Manufacturer for Outdoor RF Equipment
A large die-cast aluminum enclosure with an integrated finned surface, defined internal space, pole or wall mounting, and configurable interfaces for outdoor electronic equipment.
AY2G-220W Die Cast Aluminum Heat Sink Housing
AY2G-220W is a large die-cast aluminum heat sink housing for outdoor electronic equipment that requires a defined installation space, a finned heat-dissipation surface and configurable external interfaces. As part of the AY Power/2G Series, it is designed for equipment integration in communication, RF, security, monitoring and outdoor power applications.
The 603 × 445 × 226 mm external envelope and 552 × 358 × 142 mm internal space give engineering teams a clear starting point for checking equipment fit, mounting hardware, thermal interfaces, cable routing and service clearance.
AY2G-220W Specifications
Detailed technical parameters for the AY2G-220W aluminum heat sink enclosure.
| Model | AY2G-220W |
|---|---|
| Series | Power/2G |
| Overall Size | 603 × 445 × 226 mm |
| Internal Size | 552 × 358 × 142 mm |
| Weight | 20.7 kg |
| Material | Aluminum |
| Processing Method | Die Cast Aluminum |
| Surface Treatment | Electrostatic Spraying |
| Standard Color | Brown |
| Listed Protection Level | IP67 |
| Impact Resistance | IK10 |
| Installation | Pole / Wall Mounting |
| Operating Temperature | -40±3°C to +105±2°C |
| Operating Humidity | ≤90% RH |
| Operating Voltage | AC100–AC250V |
| Operating Power | 220–260W |
| Customizable Options | Color, inner structure, external interface |
| Additional Processing | Tapping and milling |
| Marking Options | Nameplate, silk screen and laser |
Please confirm the equipment envelope, heat-source location, cable-entry layout, mounting method and final sealing requirements before ordering.
AY2G Series Specifications
Detailed dimensional and weight parameters for our heavy-duty die cast aluminium enclosures. Built for robust industrial applications.
| Model | Product Image | External Dimensions (L × W × H mm) | Internal Dimensions (L × W × H mm) | Weight (kg) |
|---|---|---|---|---|
| AY2G-100W |
|
460 × 350 × 163 | 410 × 280 × 95 | 11.8 |
| AY2G-220W |
|
603 × 445 × 226 | 552 × 358 × 142 | 20.7 |
| AY2G-240W |
|
605 × 445 × 215 | 550 × 360 × 140 | 21.1 |
| AY2G-260W |
|
610 × 420 × 285 | 540 × 355 × 190 | 27.1 |
Finned Aluminum Enclosure for Equipment-Level Thermal Planning
The AY2G-220W housing uses an integrated finned aluminum structure to provide a larger external surface for enclosure-level heat dissipation. The enclosure can be evaluated as part of a passive or assisted thermal-management design, depending on the installed equipment, heat load, thermal interface, mounting orientation and ambient conditions.
Integrated Finned Surface
The finned surface provides a defined heat-dissipation area for equipment designers reviewing enclosure-level thermal management.
Die Cast Aluminum Construction
The die-cast aluminum body combines a rigid enclosure structure with a machinable platform for project-specific interfaces and mounting details.
Large Internal Space
The 552 × 358 × 142 mm internal space supports layout review for power modules, RF equipment, communication electronics, cable routing and service access.
Technical Note: The enclosure does not replace complete system-level thermal validation. Confirm the actual heat load, thermal contact method, airflow, orientation and ambient temperature for the final application.
Outdoor Aluminum Enclosure for Communication and Power Equipment
The AY2G-220W specification lists an IP67 protection level and IK10 impact resistance. The enclosure is also specified for pole or wall mounting, making the platform suitable for outdoor equipment integration where enclosure size, mounting position, heat dissipation and interface layout must be reviewed together.
- Die-cast aluminum enclosure body
- Listed IP67 protection level
- IK10 impact resistance
- Pole or wall mounting
Designed Around Outdoor Equipment Integration
Addressing the core requirements for engineering teams selecting a custom heat sink housing.
Need a large housing for power or RF equipment?
AY2G-220W provides a 552 × 358 × 142 mm listed internal space for checking equipment fit, component arrangement and service clearance.
Need an enclosure with an integrated heat-dissipation surface?
The finned aluminum structure provides an enclosure-level thermal surface that can be reviewed together with the equipment heat load and installation orientation.
Need to mount the enclosure outdoors?
The product specification lists pole and wall mounting. Confirm the mounting bracket, fastener and structural-load requirements for the final installation.
Need customized cable entries or external interfaces?
The listed customization scope includes inner structure, external interface, tapping, milling, nameplate, silk-screen marking and laser marking.
Need to coordinate a project-specific enclosure?
Share the equipment dimensions, heat-load information, mounting method, connector layout and required quantity so the enclosure configuration can be reviewed before production.
Typical Applications for AY2G-220W
AY2G-220W can be evaluated for communication, RF, security, monitoring, IoT, digital television and outdoor power equipment that requires a large aluminum housing. Confirm the equipment layout, heat load, interfaces, mounting arrangement and environmental requirements before final selection.
Custom Aluminum Heat Sink Housing for Project Integration
Use AY2G-220W as a starting platform for project-specific enclosure development. Customization can be reviewed around the internal equipment layout, cable entries, external interfaces, mounting details, surface finish and product identification.
Customization Options:
Project Workflow:
- 1 Share your equipment requirements
- 2 Review dimensions, heat load and interfaces
- 3 Confirm drawings and customization details
- 4 Arrange sample or pre-production review when required
- 5 Proceed with production and quality inspection
What to Confirm Before Ordering AY2G-220W
The most useful quotation information is not only the enclosure size. Please also provide the equipment layout, heat-source position, cable-entry requirements, mounting method, operating environment and expected quantity.
- Equipment overall dimensions
- Required internal mounting area
- Heat-source location
- Thermal interface & heat-load
- Cable-entry & connector positions
- Pole or wall mounting method
- Required operating voltage
- Outdoor environment
- Surface treatment and color
- Marking requirements
- Estimated quantity
- Required inspection documents
Work With an Aluminum Enclosure Manufacturer
Foshan Anyiyao Electrical Equipment Co., Ltd. focuses on outdoor enclosure development, production coordination, customization and quality control for communication, surveillance, CATV, power distribution and industrial electronic equipment.
For AY2G-220W projects, buyers can provide equipment dimensions, heat-load information, connector locations, mounting requirements, cable-entry details and surface-finish expectations for technical review.
AY2G-220W Custom Aluminum Heat Sink Housing FAQ
What is the internal size of AY2G-220W?
What is the overall size and weight?
Is AY2G-220W suitable for RF equipment?
Does the finned structure guarantee passive cooling?
Is AY2G-220W an IP67 aluminum enclosure?
Can the enclosure be customized?
What information is needed for a quotation?
Request a Quote
Please share your equipment dimensions, heat-load information, mounting method, cable-entry requirements, quantity and target application so we can review the AY2G-220W configuration.