AY321-Fan-30W RRU Die Cast Aluminum Housing Manufacturer
IP67 and IK10 Aluminum Enclosure with Four-Fan Active Cooling for Outdoor Radio and Telecom Equipment
321 × 231 × 135 mm overall size · 300 × 210 × 80 mm internal space · Four-fan cooling configuration
AY321-Fan-30W RRU Die Cast Aluminum Housing
AY321-Fan-30W is a die cast aluminum housing for Remote Radio Units, outdoor radio equipment, communication repeaters, RF remote units and other electronic assemblies.
The enclosure combines a defined internal cavity with a four-fan active cooling configuration. Its structure supports equipment layout planning, cable routing, service access and customized external interfaces for telecom applications.
The product parameter sheet identifies AY321-Fan-30W with an IP67 protection level and IK10 impact resistance. The final protection performance depends on the approved enclosure configuration, gaskets, fasteners, cable entries and complete assembly.
Foshan Anyiyao Electrical Equipment Co., Ltd. can review internal structure, mounting, external interfaces, tapping, milling, nameplates, silk screen and laser marking according to the customer’s drawing.
The housing does not provide radio communication, RF transmission, signal processing or network functions by itself. Final thermal, RF, EMC and environmental performance must be validated with the complete equipment.
Core Features of AY321-Fan-30W
Four-Fan Active Cooling Configuration
The visible four-fan panel supports active airflow planning for electronics installed inside the enclosure.
Die Cast Aluminum Construction
The aluminum enclosure provides a defined mechanical boundary for RRU, RF and telecom equipment integration.
IP67 Protection Level
AY321-Fan-30W is identified with an IP67 protection level in the product parameter sheet. Confirm the final tested configuration before production.
IK10 Impact Resistance
The product parameter sheet identifies IK10 impact resistance for this model configuration.
Pole or Wall Mounting
The standard parameter sheet identifies pole or wall mounting as the installation method. Confirm the final bracket and mounting interface according to the project drawing.
Custom External Interfaces
External openings, cable entries, mounting features, tapping, milling, nameplates, silk screen and laser marking can be reviewed according to approved drawings.
AY321-Fan-30W Specifications
| Item | AY321-Fan-30W Specification |
|---|---|
| Model | AY321-Fan-30W |
| Series | Power / 321 |
| Product Type | RRU Die Cast Aluminum Housing |
| Overall Size | 321 × 231 × 135 mm |
| Internal Size | 300 × 210 × 80 mm |
| Cooling Configuration | Four-fan active cooling panel |
| Material | Aluminum |
| Processing Method | Die Cast Aluminum |
| Protection Level | IP67, according to the product parameter sheet |
| Impact Resistance | IK10, according to the product parameter sheet |
| Installation | Pole or wall mounting |
| Surface Treatment | Electrostatic spraying |
| Operating Voltage | AC100–AC250V |
| Operating Power | 10–30W |
| Operating Humidity | ≤90% RH |
| Operating Temperature | -40±3°C to +105±2°C, as listed in the product parameter sheet |
| Weight | Confirm final fan and back-panel configuration |
| Manufacturer | Foshan Anyiyao Electrical Equipment Co., Ltd. |
Dimensions and technical values are based on the AY321-Fan-30W product parameter sheet. Confirm the latest approved drawing, fan arrangement, back-panel configuration and testing scope before production.
A Defined Housing for RRU and Radio Equipment Integration
Remote Radio Units and outdoor radio assemblies require more than an enclosure outline. The housing must be coordinated with radio modules, boards, power components, connectors, cable routing, mounting and maintenance access.
For AY321-Fan-30W, the main design review points include:
- internal equipment envelope;
- PCB and module mounting;
- fan airflow direction;
- connector and cable-entry locations;
- service clearance;
- grounding and bonding requirements;
- pole or wall mounting;
- gasket and fastener arrangement;
- external interface layout;
- final equipment assembly.
The enclosure provides the mechanical and cooling platform. It does not determine the communication performance, RF output or EMC result of the finished radio system.
Active Cooling for Compact Radio Equipment
AY321-Fan-30W uses a four-fan active cooling configuration. This configuration should be evaluated together with the internal heat load, fan airflow, component placement, ventilation path and installation environment.
Before confirming the enclosure, review:
- heat generated by each internal component;
- fan airflow direction;
- air inlet and outlet clearance;
- obstruction around the fan panel;
- dust and moisture exposure;
- fan power and control requirements;
- service access for fan replacement;
- cable and connector positions;
- system-level thermal validation.
The four-fan configuration does not guarantee a specific cooling capacity, thermal resistance or operating temperature. The finished radio assembly should be validated under its actual load and installation conditions.
Outdoor Installation Review for RRU Enclosures
AY321-Fan-30W is intended for evaluation in outdoor radio and telecom equipment applications. Its product parameter sheet identifies IP67 protection, IK10 impact resistance and pole or wall mounting.
For a complete outdoor assembly, also confirm:
- mounting orientation;
- bracket and fastener design;
- gasket compression;
- cable glands and connectors;
- fan-panel protection;
- drainage and condensation control;
- maintenance access;
- exposure to rain, dust, humidity and temperature;
- final protection testing.
The enclosure specification must be matched with the complete RRU or telecom equipment assembly. Do not treat the enclosure rating as an automatic certification for the finished system.
Addressing RRU Housing Challenges
| Buyer Concern | AY321-Fan-30W Response |
|---|---|
| Radio modules generate heat inside a compact housing | The four-fan configuration provides an active airflow path for system-level thermal planning |
| The enclosure must fit a defined radio module | The 300 × 210 × 80 mm internal space supports early equipment-layout review |
| Outdoor equipment requires environmental protection | The model is identified with IP67 protection and IK10 impact resistance in the product parameter sheet |
| Pole or wall installation changes the enclosure interface | The standard installation direction is pole or wall mounting, with final mounting details confirmed by drawing |
| Connectors and cable entries vary between projects | External interfaces and cable-entry details can be customized |
| Maintenance access is limited after installation | Fan access, service clearance and panel arrangement can be reviewed before drawing approval |
| Generic housings require extra machining | Tapping, milling, nameplates, silk screen and laser marking can be coordinated during customization |
Customize the RRU Housing Around Your Equipment
AY321-Fan-30W can be reviewed for project-specific modifications, including:
- internal mounting structure;
- PCB or module supports;
- external connector openings;
- cable entries;
- pole or wall mounting interfaces;
- tapping and milling;
- fan-panel details;
- surface finish and color;
- nameplates;
- silk-screen printing;
- laser marking;
- packaging and assembly requirements.
Project Workflow
-
1
Share the RRU or radio-equipment outline and internal component layout.
-
2
Confirm cooling direction, cable entries and mounting conditions.
-
3
Review the enclosure drawing and interface details.
-
4
Confirm the final fan and back-panel configuration.
-
5
Arrange sample or pre-production confirmation when required.
-
6
Proceed with production, inspection, packing and delivery according to the approved specification.
Aluminum Enclosure Manufacturing Support from Foshan Anyiyao
Foshan Anyiyao Electrical Equipment Co., Ltd. provides aluminum enclosure solutions for communication equipment, outdoor electronics, surveillance systems, CATV, power distribution and industrial electronic applications.
For RRU housing projects, the manufacturing discussion can include enclosure dimensions, die-cast structure, fan-panel arrangement, external interfaces, mounting details, surface treatment, marking and inspection criteria.
The project workflow can cover requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, production, inspection, packing and delivery according to the approved specification.
Frequently Asked Questions
What is AY321-Fan-30W used for?
What are the dimensions of AY321-Fan-30W?
Does AY321-Fan-30W include active cooling?
Is AY321-Fan-30W IP67 rated?
Is the housing impact resistant?
Can AY321-Fan-30W be pole-mounted or wall-mounted?
What is the operating voltage and power?
Can the external interfaces be customized?
Does the enclosure provide RF shielding?
What information is needed for a quotation?
Discuss Your RRU Die Cast Aluminum Housing Requirement
Share your radio-unit dimensions, internal module layout, fan arrangement, connector requirements or 3D drawing. Our team can review whether AY321-Fan-30W is suitable for your RRU or outdoor telecom equipment project.