AY321-Fan-30W RRU die cast aluminum housing with four-fan active cooling

AY321-Fan-30W RRU Die Cast Aluminum Housing Manufacturer

IP67 and IK10 Aluminum Enclosure with Four-Fan Active Cooling for Outdoor Radio and Telecom Equipment

321 × 231 × 135 mm overall size · 300 × 210 × 80 mm internal space · Four-fan cooling configuration

AY321-Fan-30W RRU Die Cast Aluminum Housing

AY321-Fan-30W is a die cast aluminum housing for Remote Radio Units, outdoor radio equipment, communication repeaters, RF remote units and other electronic assemblies.

The enclosure combines a defined internal cavity with a four-fan active cooling configuration. Its structure supports equipment layout planning, cable routing, service access and customized external interfaces for telecom applications.

The product parameter sheet identifies AY321-Fan-30W with an IP67 protection level and IK10 impact resistance. The final protection performance depends on the approved enclosure configuration, gaskets, fasteners, cable entries and complete assembly.

Foshan Anyiyao Electrical Equipment Co., Ltd. can review internal structure, mounting, external interfaces, tapping, milling, nameplates, silk screen and laser marking according to the customer’s drawing.

The housing does not provide radio communication, RF transmission, signal processing or network functions by itself. Final thermal, RF, EMC and environmental performance must be validated with the complete equipment.

Core Features of AY321-Fan-30W

Four-Fan Active Cooling Configuration

The visible four-fan panel supports active airflow planning for electronics installed inside the enclosure.

Die Cast Aluminum Construction

The aluminum enclosure provides a defined mechanical boundary for RRU, RF and telecom equipment integration.

IP67 Protection Level

AY321-Fan-30W is identified with an IP67 protection level in the product parameter sheet. Confirm the final tested configuration before production.

IK10 Impact Resistance

The product parameter sheet identifies IK10 impact resistance for this model configuration.

Pole or Wall Mounting

The standard parameter sheet identifies pole or wall mounting as the installation method. Confirm the final bracket and mounting interface according to the project drawing.

Custom External Interfaces

External openings, cable entries, mounting features, tapping, milling, nameplates, silk screen and laser marking can be reviewed according to approved drawings.

AY321-Fan-30W Specifications

Item AY321-Fan-30W Specification
Model AY321-Fan-30W
Series Power / 321
Product Type RRU Die Cast Aluminum Housing
Overall Size 321 × 231 × 135 mm
Internal Size 300 × 210 × 80 mm
Cooling Configuration Four-fan active cooling panel
Material Aluminum
Processing Method Die Cast Aluminum
Protection Level IP67, according to the product parameter sheet
Impact Resistance IK10, according to the product parameter sheet
Installation Pole or wall mounting
Surface Treatment Electrostatic spraying
Operating Voltage AC100–AC250V
Operating Power 10–30W
Operating Humidity ≤90% RH
Operating Temperature -40±3°C to +105±2°C, as listed in the product parameter sheet
Weight Confirm final fan and back-panel configuration
Manufacturer Foshan Anyiyao Electrical Equipment Co., Ltd.

Dimensions and technical values are based on the AY321-Fan-30W product parameter sheet. Confirm the latest approved drawing, fan arrangement, back-panel configuration and testing scope before production.

A Defined Housing for RRU and Radio Equipment Integration

Remote Radio Units and outdoor radio assemblies require more than an enclosure outline. The housing must be coordinated with radio modules, boards, power components, connectors, cable routing, mounting and maintenance access.

For AY321-Fan-30W, the main design review points include:

  • internal equipment envelope;
  • PCB and module mounting;
  • fan airflow direction;
  • connector and cable-entry locations;
  • service clearance;
  • grounding and bonding requirements;
  • pole or wall mounting;
  • gasket and fastener arrangement;
  • external interface layout;
  • final equipment assembly.

The enclosure provides the mechanical and cooling platform. It does not determine the communication performance, RF output or EMC result of the finished radio system.

AY321-Fan-30W RRU die cast aluminum housing
AY321-Fan-30W four-fan active cooling enclosure

Active Cooling for Compact Radio Equipment

AY321-Fan-30W uses a four-fan active cooling configuration. This configuration should be evaluated together with the internal heat load, fan airflow, component placement, ventilation path and installation environment.

Before confirming the enclosure, review:

  • heat generated by each internal component;
  • fan airflow direction;
  • air inlet and outlet clearance;
  • obstruction around the fan panel;
  • dust and moisture exposure;
  • fan power and control requirements;
  • service access for fan replacement;
  • cable and connector positions;
  • system-level thermal validation.

The four-fan configuration does not guarantee a specific cooling capacity, thermal resistance or operating temperature. The finished radio assembly should be validated under its actual load and installation conditions.

Outdoor Installation Review for RRU Enclosures

AY321-Fan-30W is intended for evaluation in outdoor radio and telecom equipment applications. Its product parameter sheet identifies IP67 protection, IK10 impact resistance and pole or wall mounting.

For a complete outdoor assembly, also confirm:

  • mounting orientation;
  • bracket and fastener design;
  • gasket compression;
  • cable glands and connectors;
  • fan-panel protection;
  • drainage and condensation control;
  • maintenance access;
  • exposure to rain, dust, humidity and temperature;
  • final protection testing.

The enclosure specification must be matched with the complete RRU or telecom equipment assembly. Do not treat the enclosure rating as an automatic certification for the finished system.

AY321-Fan-30W outdoor RRU aluminum housing

Addressing RRU Housing Challenges

Buyer Concern AY321-Fan-30W Response
Radio modules generate heat inside a compact housing The four-fan configuration provides an active airflow path for system-level thermal planning
The enclosure must fit a defined radio module The 300 × 210 × 80 mm internal space supports early equipment-layout review
Outdoor equipment requires environmental protection The model is identified with IP67 protection and IK10 impact resistance in the product parameter sheet
Pole or wall installation changes the enclosure interface The standard installation direction is pole or wall mounting, with final mounting details confirmed by drawing
Connectors and cable entries vary between projects External interfaces and cable-entry details can be customized
Maintenance access is limited after installation Fan access, service clearance and panel arrangement can be reviewed before drawing approval
Generic housings require extra machining Tapping, milling, nameplates, silk screen and laser marking can be coordinated during customization

Customize the RRU Housing Around Your Equipment

AY321-Fan-30W can be reviewed for project-specific modifications, including:

  • internal mounting structure;
  • PCB or module supports;
  • external connector openings;
  • cable entries;
  • pole or wall mounting interfaces;
  • tapping and milling;
  • fan-panel details;
  • surface finish and color;
  • nameplates;
  • silk-screen printing;
  • laser marking;
  • packaging and assembly requirements.

Project Workflow

  1. 1

    Share the RRU or radio-equipment outline and internal component layout.

  2. 2

    Confirm cooling direction, cable entries and mounting conditions.

  3. 3

    Review the enclosure drawing and interface details.

  4. 4

    Confirm the final fan and back-panel configuration.

  5. 5

    Arrange sample or pre-production confirmation when required.

  6. 6

    Proceed with production, inspection, packing and delivery according to the approved specification.

Aluminum Enclosure Manufacturing Support from Foshan Anyiyao

Foshan Anyiyao Electrical Equipment Co., Ltd. provides aluminum enclosure solutions for communication equipment, outdoor electronics, surveillance systems, CATV, power distribution and industrial electronic applications.

For RRU housing projects, the manufacturing discussion can include enclosure dimensions, die-cast structure, fan-panel arrangement, external interfaces, mounting details, surface treatment, marking and inspection criteria.

The project workflow can cover requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, production, inspection, packing and delivery according to the approved specification.

aluminum RRU enclosure manufacturing process

Frequently Asked Questions

What is AY321-Fan-30W used for?
AY321-Fan-30W is a die cast aluminum RRU housing for outdoor radio equipment, communication base stations, repeaters, RF remote units, surveillance electronics and other telecom assemblies.
What are the dimensions of AY321-Fan-30W?
The reference overall size is 321 × 231 × 135 mm. The reference internal size is 300 × 210 × 80 mm. Confirm the latest approved drawing before production.
Does AY321-Fan-30W include active cooling?
Yes. The model is shown with a four-fan active cooling panel. Fan arrangement, airflow direction, power connection and replacement access should be confirmed for the complete equipment design.
Is AY321-Fan-30W IP67 rated?
The product parameter sheet identifies AY321-Fan-30W with an IP67 protection level. Confirm the final enclosure configuration, sealing components and applicable testing scope before production.
Is the housing impact resistant?
The product parameter sheet identifies IK10 impact resistance for the model configuration. Confirm the final tested configuration and installation condition for the complete assembly.
Can AY321-Fan-30W be pole-mounted or wall-mounted?
Yes. Pole or wall mounting is identified in the standard parameter sheet. Confirm the bracket, fastener and mounting interface according to the project drawing.
What is the operating voltage and power?
The product parameter sheet lists AC100–AC250V operating voltage and 10–30W operating power. Confirm the requirements of the installed fans and complete equipment before production.
Can the external interfaces be customized?
Yes. Cable entries, openings, mounting points, tapping, milling, nameplates, silk screen and laser marking can be reviewed according to approved drawings.
Does the enclosure provide RF shielding?
RF shielding and EMC performance should not be assumed from the aluminum housing alone. Grounding, bonding, seams, connectors and the complete radio assembly must be evaluated where required.
What information is needed for a quotation?
Provide the RRU dimensions, internal module layout, fan requirements, connector positions, cable-entry locations, mounting method, surface treatment, quantity and available drawings or 3D files.

Discuss Your RRU Die Cast Aluminum Housing Requirement

Share your radio-unit dimensions, internal module layout, fan arrangement, connector requirements or 3D drawing. Our team can review whether AY321-Fan-30W is suitable for your RRU or outdoor telecom equipment project.

sales@aysolarbox.com
+8618038893519

Supported formats: PDF, JPG, PNG, STEP, IGES, STL, DWG (Max 20MB)