AY490-270W Telecom Equipment Enclosure Manufacturer
Finned Die Cast Aluminum Enclosure for Outdoor Communication and Electronic Equipment
490 × 410 × 233 mm external size · 462 × 382 × 140 mm internal space · 18.5 kg reference weight
AY490-270W Die Cast Aluminum Telecom Equipment Enclosure
AY490-270W is a finned die cast aluminum telecom equipment enclosure designed for communication modules, outdoor electronic assemblies, RF equipment and industrial control electronics.
Its defined internal space supports early planning for boards, power components, connectors, cable routing and service access. The external finned surface provides a basis for thermal-management evaluation when the enclosure is integrated with heat-generating electronics.
Foshan Anyiyao Electrical Equipment Co., Ltd. can review the internal arrangement, mounting points, openings, cable entries, panels, finish and marking according to the customer’s approved drawing.
Note: AY490-270W is an enclosure component only. It does not provide communication, RF transmission, power conversion, cooling control or environmental protection by itself. Final thermal, sealing, EMC and outdoor performance must be verified with the complete assembly.
Core Structural Features
A defined mechanical boundary for telecom and outdoor electronic equipment integration.
Finned External Surface
The visible finned structure provides a surface for heat-management planning around electronic components.
Defined Internal Space
The 462 × 382 × 140 mm reference internal space helps engineers plan component placement, cable routing and service clearance.
Die Cast Aluminum Housing
The rigid aluminum enclosure creates a defined mechanical boundary for telecom and outdoor electronic equipment.
Custom Interface Preparation
Connector openings, cable entries, threaded holes, mounting points, panels and marking can be reviewed against approved drawings.
Equipment-Level Integration
The enclosure can be evaluated for telecom modules, RF electronics, surveillance systems, industrial controls and outdoor power electronics.
AY490-270W Specifications
| Item | AY490-270W Specification |
|---|---|
| Model | AY490-270W |
| Series | AY490 |
| Product Type | Finned Die Cast Aluminum Telecom Equipment Enclosure |
| External Dimension | 490 × 410 × 233 mm |
| Internal Dimension | 462 × 382 × 140 mm |
| Reference Weight | 18.5 kg |
| Construction Description | Die cast aluminum enclosure with external finned surface |
| Typical Integration | Telecom equipment, communication modules, RF electronics and outdoor electronic assemblies |
| Customization Scope | Cutouts, cable entries, mounting points, threaded holes, panels, finish, labels and marking |
| Manufacturer | Foshan Anyiyao Electrical Equipment Co., Ltd. |
Dimensions and weight are reference values for AY490-270W. Confirm the latest approved drawing before production. Final weight and configuration may change after openings, machining, panels, surface treatment or other approved modifications.
A Defined Housing for Telecom Equipment Integration
Telecom and communication equipment often combines boards, power components, connectors and cable interfaces in a limited mechanical space. The enclosure must therefore be evaluated together with the equipment layout, installation method and service requirements.
For AY490-270W, the main review points include:
- internal equipment envelope;
- PCB or module mounting;
- power-component position;
- connector and cable-entry locations;
- clearance around heat-generating components;
- service and maintenance access;
- mounting method;
- external panel arrangement;
- gasket and fastener requirements;
- installation environment.
A defined enclosure size helps engineers identify dimensional conflicts before drawing approval. Final compatibility depends on the customer’s complete equipment layout and interface requirements.
Thermal and Outdoor Installation Review
The external fins of AY490-270W provide a basis for thermal-design evaluation, but actual heat dissipation depends on the installed electronics and the complete installation condition.
Before selecting the housing, review:
- actual heat generated by internal components;
- contact between heat sources and the enclosure;
- thermal-interface materials;
- fin orientation;
- surrounding airflow;
- solar exposure and installation position;
- cable-entry and connector locations;
- gasket and fastener arrangement;
- service access;
- prototype or system-level validation requirements.
AY490-270W does not guarantee a specific thermal resistance, cooling capacity, operating temperature or passive-cooling result. Outdoor sealing and environmental protection must also be reviewed at the complete assembly level.
Application Integrations
The enclosure does not provide communication, RF transmission, surveillance or control functions by itself. It serves as a mechanical housing for:
Telecom Equipment Enclosure
For communication modules and telecom electronics where internal space, connectors, cable routing and maintenance access must be coordinated.
Outdoor Communication Equipment Housing
For outdoor electronic equipment requiring a defined aluminum enclosure and project-specific interface review.
RF Equipment Housing
For RF modules and electronic assemblies where enclosure dimensions, thermal paths and connector positions must be evaluated together.
Industrial Electronic Enclosure
For control units, power electronics and industrial modules that require a rigid custom housing structure.
Surveillance and Security Electronics Housing
For surveillance or security equipment that needs enclosure integration, mounting review and service access.
Engineering Coordination & Responses
Buyer Concern
Internal communication modules do not fit standard boxes
AY490-270W Response
The defined internal size supports early equipment-envelope planning
Buyer Concern
Connectors and cable entries are located differently for each project
AY490-270W Response
Openings and cable-entry positions can be reviewed against approved drawings
Buyer Concern
Heat-generating components are installed in a compact housing
AY490-270W Response
The external finned surface provides a basis for thermal design review
Buyer Concern
Outdoor installation requires coordinated interfaces
AY490-270W Response
Mounting, fasteners, gaskets, cable entries and service access can be reviewed together
Buyer Concern
Maintenance access is difficult to plan
AY490-270W Response
Panels and service areas can be considered during the enclosure-layout review
Buyer Concern
Custom machining creates coordination risks
AY490-270W Response
Drawing confirmation allows interfaces, holes, labels and finish requirements to be clarified before production
Outdoor Telecom Enclosure Selection Checklist
For outdoor use, do not evaluate an enclosure by size alone. Confirm the complete equipment environment before production:
Anyiyao can review the housing structure and interface requirements, but the final protection level must be confirmed through the complete assembly, approved components and applicable validation.
Customize the Enclosure Around Your Telecom Equipment
AY490-270W can be reviewed for project-specific modifications, including:
Project Workflow:
-
1
Share the equipment outline, internal components and installation environment.
-
2
Review the enclosure size, thermal path, mounting method and interface locations.
-
3
Confirm the drawing and modification details.
-
4
Arrange sample or pre-production confirmation when required.
-
5
Proceed with production, inspection, packing and delivery according to the approved specification.
Aluminum Enclosure Manufacturing Support from Foshan Anyiyao
Foshan Anyiyao Electrical Equipment Co., Ltd. provides aluminum enclosure solutions for outdoor electronics, communication equipment, surveillance systems, CATV, power distribution and industrial electronic applications.
For an AY490-270W project, the manufacturing discussion can include enclosure dimensions, internal arrangement, heat-management features, openings, mounting details, cable routing, surface requirements and inspection criteria.
The project workflow can cover requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, production, inspection, packing and delivery according to the approved specification.
Frequently Asked Questions
What is AY490-270W used for?
What are the dimensions of AY490-270W?
How much does AY490-270W weigh?
Does AY490-270W guarantee passive cooling?
Can AY490-270W be used as an outdoor telecom equipment enclosure?
Can the enclosure be customized?
Does the housing have an IP or NEMA rating?
Can RF equipment be installed inside AY490-270W?
What information is needed for a quotation?
Discuss Your Telecom Equipment Enclosure Requirement
Share your equipment dimensions, internal module layout, connector requirements or 3D drawing. Our team can review whether AY490-270W or a customized die cast aluminum enclosure is suitable for your telecom or outdoor electronics project.