AY500-200W die-cast aluminum RF housing

AY500-200W Die Cast Aluminum RF Housing Manufacturer

A finned die-cast aluminum enclosure for outdoor RF, communication and power equipment, with defined installation space, listed IP67 protection and configurable interfaces.

500 × 440 × 235 mm overall size 465 × 383 × 140 mm internal size 20–300W listed operating power

Please provide the installed equipment dimensions, heat load, connector layout, mounting method and required openings for enclosure evaluation.

AY500-200W Aluminum Heat Sink Enclosure

AY500-200W is a die-cast aluminum RF housing designed for outdoor electronic equipment integration. Its finned aluminum structure provides an external heat-dissipation surface, while the defined internal cavity supports equipment layout, cable routing and service-clearance planning.

The enclosure can be evaluated for RF power amplifier assemblies, telecom equipment, communication base-station equipment, repeaters, RF remote units, security systems, video surveillance, IoT equipment, digital TV relay equipment and outdoor power electronics.

Foshan Anyiyao Electrical Equipment Co., Ltd. can review the required internal structure, cable entries, mounting points, external interfaces and identification requirements before production.

Important Note: AY500-200W is a mechanical housing. It does not provide RF amplification, signal transmission, EMC performance or RF shielding effectiveness by itself. Any shielding, grounding or electromagnetic compatibility requirement must be evaluated for the complete assembled system.

Finned Die-Cast Aluminum Construction

AY500-200W aluminum heat sink enclosure with external fins

Finned Aluminum Heat-Dissipation Structure

The external fins provide an expanded heat-dissipation surface for passive or assisted thermal-management planning.

AY500-200W outdoor die-cast aluminum enclosure

Die-Cast Aluminum RF Housing

The die-cast aluminum body provides a rigid enclosure platform for RF, communication, power and control modules.

AY500-200W aluminum heat sink housing with internal dimensions

Defined Internal Installation Space

The 465 × 383 × 140 mm internal space helps engineers evaluate equipment dimensions, connector clearance and cable routing before quotation.

Outdoor Equipment Protection

The product specification lists IP67 protection, while the complete sealing result depends on the assembled enclosure, gaskets, cable entries and customized openings.

Pole or Wall Mounting

The AY500-200W product specification lists pole or wall mounting as the installation method.

Custom Interface Configuration

Internal structure, external interfaces, color, tapping, milling, nameplates, silk screen and laser marking can be reviewed according to project requirements.

Product Specifications

Model AY500-200W
Product Type Die Cast Aluminum RF Housing
Series Power / 500
Brand AY
Material Aluminum
Processing Method Die-cast aluminum
Color Silver Grey
Surface Treatment Electrostatic spraying
Overall Size 500 × 440 × 235 mm
Internal Size 465 × 383 × 140 mm
Weight 20 kg
Protection Level IP67 model reference, subject to complete assembly confirmation
Impact Resistance IK10
Installation Pole or wall mounting
Operating Temperature -40 ± 3°C to +105 ± 2°C
Operating Humidity ≤90% RH
Operating Voltage AC100–AC250V
Listed Operating Power 20–300W
Customizable Parameters Color, internal structure, external interfaces, tapping, milling, nameplate, silk screen and laser marking
Manufacturer Foshan Anyiyao Electrical Equipment Co., Ltd.

AY500 Series Specifications

Detailed technical specifications for our premium die-cast aluminium enclosures. Engineered for precision, durability, and reliable protection in demanding environments.

Model: AY500-100W

  • Outer Dimensions 500*440*140 mm
  • Inner Dimensions 464*384*80 mm
  • Weight 15.5 kg

Model: AY500-150W

  • Outer Dimensions 500*440*187 mm
  • Inner Dimensions 465*383*110 mm
  • Weight 16.8 kg

Model: AY500-200W

  • Outer Dimensions 500*440*235 mm
  • Inner Dimensions 465*383*140 mm
  • Weight 20.0 kg

Need custom dimensions or bulk pricing? Contact our engineering team directly: sales@aysolarbox.com +8618038893519

How to Evaluate AY500-200W Heat Dissipation

The finned structure provides a heat-dissipation surface, but the enclosure’s thermal suitability cannot be determined from the model name or listed operating power alone. The actual heat load, component losses, ambient temperature, solar exposure, installation orientation, wall contact, internal layout and allowable internal temperature must be considered together.

01

Separate operating power from heat load

The listed operating power is 20–300W. This figure should not be treated as the heat released by the installed equipment. Confirm the actual electrical losses and total heat load before selecting the cooling arrangement.

02

Check the internal envelope

Compare the 465 × 383 × 140 mm internal space with the equipment dimensions, connector clearance, cable bend radius, insulation distance and service access requirements.

03

Keep the fins effective

Avoid covering the finned surfaces. Confirm whether the final orientation allows natural convection and whether nearby structures block the available heat-dissipation area.

04

Balance cooling and sealing

A sealed IP67 configuration can limit natural airflow. If the installed equipment needs assisted cooling, the fan, heat exchanger, thermal interface or external cooling arrangement must be designed together with the sealing strategy.

05

Validate the complete assembly

Final passive-cooling suitability should be confirmed through thermal calculation, prototype testing or simulation using the actual RF equipment, heat load and installation environment.

Send us the equipment heat load, ambient temperature range, installation orientation and internal component layout so we can review the enclosure configuration.

AY500-200W RF power amplifier housing

What to Confirm Before Choosing a Die-Cast Aluminum RF Housing

RF housing selection should start with the installed equipment rather than the enclosure name. Confirm the board or module dimensions, connector locations, cable entries, mounting points, thermal load, environmental exposure and required service access before finalizing the enclosure.

  • Internal equipment dimensions
  • Connector and cable clearance
  • Mounting method
  • Required external openings
  • Heat load and cooling method
  • Gasket and sealing arrangement
  • Grounding and bonding requirements
  • Required RF or EMC validation
  • Surface finish and identification
  • Quantity and production stage

Note: Aluminum construction alone does not guarantee RF shielding effectiveness. Shielding performance depends on the complete enclosure design, lid interface, gasket, seams, apertures, connectors, grounding and test method.

Designed Around RF Equipment Integration Requirements

Need a rigid housing for outdoor RF equipment?

The aluminum die-cast body provides a defined mechanical platform for RF power amplifier assemblies, telecom modules, communication units and outdoor power electronics.

Worried about heat inside a sealed enclosure?

The finned structure provides a heat-dissipation surface for thermal planning. Final cooling suitability depends on the installed equipment and environmental conditions.

Need to fit connectors, cable entries or mounting hardware?

External interfaces, cable entry locations, mounting points and internal structure can be reviewed around the actual equipment layout.

Need to combine outdoor protection and RF system integration?

The enclosure configuration, sealing, grounding, connector layout and thermal design should be reviewed together before production.

Applications for AY500-200W

AY500-200W can be evaluated for the following outdoor equipment applications:

Die Cast Aluminum RF Housing RF Power Amplifier Housing Telecom Equipment Enclosure 5G communication equipment Communication base stations Repeaters RF remote units Video surveillance and IoT equipment Digital TV relay equipment Outdoor power electronics Custom outdoor electronic assemblies

Application suitability depends on the installed equipment dimensions, actual heat load, mounting method, connector arrangement, environmental conditions and required compliance testing.

AY500-200W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample, so final IP67 suitability must be confirmed for the complete AY500-200W assembly, gasket condition, fasteners, cable glands and all customized openings.

An IP67 enclosure configuration depends on the complete assembled product. Any drilling, milling, connector installation, cable entry or interface modification must be reviewed for sealing performance before production.

Custom Aluminum Heat Sink Enclosure Options

Foshan Anyiyao Electrical Equipment Co., Ltd. supports enclosure customization from requirement review to drawing confirmation, sample or pre-production review, production, inspection, packing and delivery.

Internal mounting structure
External interface openings
Cable entry locations
Pole or wall mounting points
Tapping and milling
Color options
Nameplate
Silk-screen marking
Laser marking

Share your equipment dimensions, heat load, connector layout, cable entry requirements, mounting method and estimated quantity. The engineering team can then review the enclosure configuration and confirm the manufacturability of the requested changes.

Custom Aluminum Heat Sink Housing

Aluminum Enclosure Manufacturer for RF and Telecom Equipment

Foshan Anyiyao Electrical Equipment Co., Ltd. provides outdoor enclosure design coordination, die-cast aluminum enclosure production, customization and inspection support for electronic equipment applications.

The company’s process can include requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, mass production, inspection, packing and delivery.

Outdoor aluminum enclosure customization
Die-cast aluminum production
Heat-dissipation enclosure design coordination
Internal structure and interface customization
Pole and wall mounting integration
Inspection before packing and delivery

Frequently Asked Questions

What is AY500-200W used for?
AY500-200W is a die-cast aluminum RF housing for outdoor RF, communication, power and electronic equipment integration. It can be evaluated for RF power amplifier assemblies, telecom equipment and outdoor communication systems.
What are the overall and internal dimensions?
The overall size is 500 × 440 × 235 mm. The internal size is 465 × 383 × 140 mm. Engineers should also check connector clearance, cable routing, mounting hardware and service access before final confirmation.
What is the listed operating power?
The product specification lists an operating power of 20–300W. This is not the same as the actual heat load. Thermal selection should be based on the electrical losses generated by the installed equipment.
Can AY500-200W be used as an RF Power Amplifier Housing?
It can be evaluated for RF power amplifier and related outdoor electronic assemblies. Final suitability depends on the installed equipment dimensions, heat load, interfaces, mounting and environmental requirements.
Does AY500-200W guarantee passive cooling?
No. The finned construction provides a heat-dissipation surface, but passive-cooling suitability must be confirmed using the actual heat load, ambient conditions, installation orientation and complete assembly.
Is AY500-200W independently tested for IP67?
AY500-200W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample. Final sealing performance must be confirmed for the complete AY500-200W assembly and customized openings.
Does the aluminum housing guarantee RF shielding?
No. RF shielding effectiveness depends on the complete enclosure design, lid interface, gasket, apertures, connectors, grounding and test method. Any RF or EMC requirement should be specified and validated separately.
What mounting options are available?
The AY500-200W product specification lists pole or wall mounting. The final mounting interface should be reviewed according to the equipment weight, installation position and project requirements.
Can the internal structure and interfaces be customized?
Yes. Internal structure, external interfaces, cable entries, color, tapping, milling, nameplates, silk-screen marking and laser marking can be reviewed according to the project requirements.
What information should I provide for a quotation?
Please provide the equipment dimensions, actual heat load, ambient temperature, installation location, mounting method, cable entry requirements, connector layout, required openings, surface finish and estimated quantity.

Ready to Evaluate the AY500-200W?

Contact Foshan Anyiyao Electrical Equipment Co., Ltd. to discuss your outdoor RF and telecom equipment enclosure requirements.