AY447-170W aluminum heat-dissipating housing
Aluminum Heat Sink Enclosure

AY447-170W Aluminum Heat-Dissipating Housing Manufacturer

A finned aluminum enclosure for outdoor RF, communication and electronic equipment, with defined internal space, external heat-dissipation surfaces and customizable interfaces.

447 × 357 × 203 mm overall size
424 × 334 × 120 mm internal size
Finned aluminum construction

Please provide the installed equipment dimensions, heat load, connector layout, mounting method and required openings for enclosure evaluation.

AY447-170W Aluminum Heat Sink Enclosure

AY447-170W is an aluminum heat-dissipating housing designed for outdoor electronic equipment integration. Its finned structure provides an external heat-dissipation surface, while the defined internal cavity supports component placement, cable routing and service-clearance planning.

The enclosure can be evaluated for RF equipment, RF power amplifier assemblies, communication units, telecom equipment, surveillance electronics, control modules and outdoor power electronics.

Foshan Anyiyao Electrical Equipment Co., Ltd. can review the required internal structure, cable entries, mounting points, external interfaces and identification requirements before production.

Note: AY447-170W is a mechanical equipment housing. It does not provide RF amplification, communication performance, EMC performance or shielding effectiveness by itself. The final equipment performance depends on the installed electronics and complete system design.

AY447-170W aluminum heat sink enclosure with external fins

Finned Aluminum Construction

Engineered to support passive cooling and secure equipment integration.

Finned Heat-Dissipation Structure

The external fins provide an expanded heat-dissipation surface for passive or assisted thermal-management planning.

Die-Cast Aluminum Enclosure

The aluminum enclosure provides a rigid mechanical platform for RF, communication, power and control modules.

Defined Internal Installation Space

The 424 × 334 × 120 mm internal space helps engineers evaluate equipment dimensions, connector clearance and cable routing before quotation.

Outdoor Equipment Integration

The housing can be evaluated for outdoor electronic assemblies that require a combination of mechanical protection and heat-dissipation planning.

Custom Interface Configuration

Internal structure, external interfaces, cable entries, tapping, milling and identification details can be reviewed according to project requirements.

AY447-170W Specifications

Model
AY447-170W
Product Type
Aluminum Heat-Dissipating Housing
Construction
Finned aluminum enclosure
Overall Size
447 × 357 × 203 mm
Internal Size
424 × 334 × 120 mm
Reference Weight
Approximately 15 kg, subject to final production configuration
Application
Outdoor electronic equipment integration
Protection
IP67 model reference, subject to complete assembly confirmation
Customization
Internal structure, external interfaces, color, tapping, milling, nameplate, silk screen and laser marking
Manufacturer
Foshan Anyiyao Electrical Equipment Co., Ltd.

Series AY447 Specifications

Review the detailed dimensions and weight parameters for the AY447 series die-cast aluminium enclosures. Select the model that best matches your industrial requirements.

Model Number Outer Dimensions (mm) Inner Dimensions (mm) Weight (kg) Action
AY447-90W 447 × 357 × 139 424 × 334 × 800 11.8
AY447-130W 447 × 357 × 171 424 × 334 × 100 12.5
AY447-170W 447 × 357 × 203 424 × 334 × 120 14.9

Looking for custom dimensions?

We provide custom OEM/ODM solutions for die-cast aluminium enclosures.

How to Evaluate AY447-170W Heat Dissipation

The finned structure provides a heat-dissipation surface, but enclosure suitability cannot be determined from the model name alone. The actual heat load, component losses, ambient temperature, solar exposure, installation orientation, wall contact, internal layout and allowable internal temperature must be considered together.

1

Confirm the actual heat load

Calculate the heat released by the installed electronics rather than using the equipment’s input power as the only reference.

2

Check the internal envelope

Compare the 424 × 334 × 120 mm internal space with the equipment dimensions, connector clearance, cable bend radius and service access requirements.

3

Keep the fins effective

Avoid covering the finned surfaces. Confirm whether the final installation position allows natural convection and whether nearby structures block the available heat-dissipation area.

4

Balance cooling and sealing

A sealed outdoor configuration can limit natural airflow. If the installed equipment needs assisted cooling, the cooling arrangement must be designed together with the sealing strategy.

5

Validate the complete assembly

Final passive-cooling suitability should be confirmed through thermal calculation, prototype testing or simulation using the actual equipment, heat load and installation environment.

Send us the equipment heat load, ambient temperature range, installation orientation and internal component layout so we can review the enclosure configuration.

Confirm AY447-170W Fit

What to Confirm Before Choosing an Aluminum Heat Sink Enclosure

An aluminum heat sink enclosure should be selected according to the installed electronics and the actual installation environment. The enclosure name or nominal equipment power is not enough to determine thermal performance.

Actual heat load
Component contact and thermal interface
Internal equipment dimensions
Connector and cable clearance
Fin orientation
Ambient temperature
Solar exposure
Wall or pole mounting position
Required sealing level
Need for passive or assisted cooling
Prototype or thermal validation requirements

The aluminum body and external fins support thermal-management planning, but the final temperature rise depends on the complete equipment assembly, heat path, installation and environment.

Designed Around Outdoor Heat-Dissipation Requirements

Need to move heat away from outdoor electronics?

The finned enclosure provides an external surface for heat-dissipation planning around the installed components.

Need a compact housing with usable internal space?

The defined internal cavity helps engineers review equipment dimensions, connector clearance and service access before production.

Worried about heat inside a sealed enclosure?

The sealing arrangement and thermal design should be evaluated together, especially when the final assembly requires outdoor protection and limited airflow.

Need to fit different connectors and cable entries?

External interfaces, cable entry locations, mounting points and internal structure can be reviewed around the actual equipment layout.

Applications for AY447-170W

AY447-170W can be evaluated for the following outdoor equipment applications:

  • Aluminum heat-dissipating housing
  • Aluminum heat sink enclosure
  • RF Equipment Housing
  • RF Power Amplifier Housing
  • Telecom Equipment Enclosure
  • Communication equipment
  • Repeater equipment
  • Surveillance and security electronics
  • Power and signal-processing equipment
  • Industrial electronic equipment
  • Custom outdoor electronic assemblies
Important: Application suitability depends on the installed equipment dimensions, actual heat load, mounting method, connector arrangement, environmental conditions and required compliance testing.

IP67 Enclosure Reference

AY447-170W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample, so final IP67 suitability must be confirmed for the complete AY447-170W assembly, gasket condition, fasteners, cable glands and all customized openings.

An IP67 enclosure configuration depends on the complete assembled product. Any drilling, milling, connector installation, cable entry or interface modification must be reviewed for sealing performance before production.

Plan RF and Communication Interfaces Around the Complete Assembly

RF and communication equipment integration requires early planning for connectors, cable routing, mounting points, grounding, sealing and service access. Interface openings should be reviewed together with the internal component layout and required environmental protection.

Aluminum construction alone does not guarantee RF shielding effectiveness. Shielding, grounding and EMC performance depend on the complete enclosure design, lid interface, gasket, apertures, connectors, bonding method and validation process.

AY447-170W outdoor die-cast aluminum enclosure

Custom Aluminum Heat Sink Housing Options

Foshan Anyiyao Electrical Equipment Co., Ltd. supports enclosure customization from requirement review to drawing confirmation, sample or pre-production review, production, inspection, packing and delivery.

Internal mounting structure
External interface openings
Cable entry locations
Mounting points
Tapping and milling
Color options
Nameplate
Silk-screen marking
Laser marking

Share your equipment dimensions, heat load, connector layout, cable entry requirements, mounting method and estimated quantity. The engineering team can then review the enclosure configuration and confirm the manufacturability of the requested changes.

Discuss Custom Interfaces
Foshan Anyiyao Electrical Equipment Co., Ltd. Logo

Aluminum Enclosure Manufacturer for Heat-Dissipating Equipment

Foshan Anyiyao Electrical Equipment Co., Ltd. provides outdoor enclosure design coordination, die-cast aluminum enclosure production, customization and inspection support for electronic equipment applications.

The company’s process can include requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, mass production, inspection, packing and delivery.

Expertise Outdoor aluminum enclosure customization
Production Die-cast aluminum production
Support Heat-dissipation enclosure design coordination
Flexibility Internal structure and interface customization
Application Compact equipment integration
Quality Inspection before packing and delivery

Frequently Asked Questions

What is AY447-170W used for?
AY447-170W is an aluminum heat-dissipating housing for outdoor RF, communication, power and electronic equipment integration. It can be evaluated for RF equipment, telecom equipment and other outdoor electronic assemblies.
What are the overall and internal dimensions?
The overall size is 447 × 357 × 203 mm. The internal size is 424 × 334 × 120 mm. Engineers should also check connector clearance, cable routing, mounting hardware and service access before final confirmation.
Does AY447-170W guarantee passive cooling?
No. The finned construction provides a heat-dissipation surface, but passive-cooling suitability must be confirmed using the actual heat load, ambient conditions, installation orientation and complete assembly.
Can AY447-170W be used as an RF Power Amplifier Housing?
It can be evaluated for RF power amplifier and related outdoor electronic assemblies. Final suitability depends on the installed equipment dimensions, heat load, interfaces, mounting and environmental requirements.
Is AY447-170W independently tested for IP67?
AY447-170W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample. Final sealing performance must be confirmed for the complete AY447-170W assembly and customized openings.
Does the aluminum housing guarantee RF shielding?
No. RF shielding effectiveness depends on the complete enclosure design, lid interface, gasket, apertures, connectors, grounding and test method. Any RF or EMC requirement should be specified and validated separately.
Can the internal structure and interfaces be customized?
Yes. Internal structure, external interfaces, cable entries, color, tapping, milling, nameplates, silk-screen marking and laser marking can be reviewed according to the project requirements.
What information should I provide for a quotation?
Please provide the equipment dimensions, actual heat load, ambient temperature, installation location, mounting method, cable entry requirements, connector layout, required openings, surface finish and estimated quantity.

Request AY447-170W Details

Contact our engineering team to discuss your Passive Cooling Aluminum Enclosure requirements.

Project Technical Details

Supported formats: PDF, JPG, PNG, STEP, IGES, STL, DWG (Max 20MB)

Please include the equipment layout or drawing if available. This helps us review internal space, interfaces, mounting, sealing and heat-dissipation requirements.