AY502-400W RF aluminum housing for Counter-UAV projects
AY502-400W Series

AY502-400W RF Aluminum Housing for Counter-UAV Projects

A finned die-cast aluminum enclosure for outdoor RF, communication, power and electronic equipment integration, with large internal space, listed IP67 protection and configurable interfaces.

502 × 390 × 305 mm overall size 465 × 365 × 140 mm internal size 400–500W listed operating power

Please provide the installed equipment dimensions, heat load, connector layout, mounting method and required openings for enclosure evaluation.

AY502-400W Aluminum Heat Sink Enclosure

AY502-400W is a large-format aluminum heat sink enclosure designed for outdoor RF, communication, power and electronic equipment integration. Its finned die-cast aluminum structure provides an external heat-dissipation surface, while the defined internal cavity supports equipment layout, cable routing and service-clearance planning.

The enclosure can be evaluated for RF equipment, counter-UAV system modules, communication units, RF power amplifier assemblies, telecom equipment, surveillance electronics, control modules and outdoor power electronics.

Foshan Anyiyao Electrical Equipment Co., Ltd. can review the required internal structure, cable entries, mounting points, external interfaces and identification requirements before production.

Important Note: AY502-400W is a mechanical housing. It does not provide drone detection, tracking, RF jamming, GPS spoofing, interception, antenna performance or command-and-control functions by itself. Those functions depend on the equipment installed inside and the complete system design.

Compliance: Counter-UAV and RF equipment must be used only in applications authorized by the applicable laws and regulations in the installation location.

AY502-400W aluminum heat sink enclosure with external fins

Finned Die-Cast Aluminum Construction

Engineered for outdoor equipment integration, balancing structural rigidity, installation space, and thermal management planning.

Large Finned Heat-Dissipation Structure

The external fins provide an expanded heat-dissipation surface for passive or assisted thermal-management planning.

Die-Cast Aluminum Enclosure

The die-cast aluminum body provides a rigid enclosure platform for RF, communication, power and control modules.

Large Internal Installation Space

The 465 × 365 × 140 mm internal space supports equipment layout, connector clearance, cable routing and service access planning.

Outdoor Equipment Protection

The product specification lists IP67 protection, while the complete sealing result depends on the assembled enclosure, gaskets, cable entries and customized openings.

Pole or Wall Mounting

The AY502-400W product specification lists pole or wall mounting as the installation method.

Custom Interface Configuration

Internal structure, external interfaces, color, tapping, milling, nameplates, silk screen and laser marking can be reviewed according to project requirements.

AY502-400W Specifications

Review the physical dimensions, materials, and listed parameters to evaluate the enclosure for your outdoor electronic equipment integration.

AY502-400W die-cast aluminum outdoor equipment enclosure
Item Specification
Model AY502-400W
Product Type RF Aluminum Housing for Counter-UAV Projects
Series Power / 502
Brand AY
Material Aluminum
Processing Method Die-cast aluminum
Color Silver Grey
Surface Treatment Electrostatic spraying
Overall Size 502 × 390 × 305 mm
Internal Size 465 × 365 × 140 mm
Weight 23.5 kg
Protection Level IP67 model reference, subject to complete assembly confirmation
Impact Resistance IK10
Installation Pole or wall mounting
Operating Temperature -40 ± 3°C to +105 ± 2°C
Operating Humidity ≤90% RH
Operating Voltage AC100–AC250V
Listed Operating Power 400–500W
Customizable Parameters Color, internal structure, external interfaces, tapping, milling, nameplate, silk screen and laser marking
Manufacturer Foshan Anyiyao Electrical Equipment Co., Ltd.

* Note: "Operating Power 400–500W" is the listed operating power range in the product specification. The actual cooling requirement must be evaluated based on equipment losses, ambient temperature, and installation method.

AY502 Series Size Comparison

Need a different capacity? Compare the current AY502-400W with our other heavy-duty die-cast aluminum enclosures in the same series to find the perfect fit for your equipment.

Model Outer Dimensions (L×W×H) Inner Dimensions (L×W×H) Weight Action
AY502-220W Compact Size
502*390*145 mm 465*365*70 mm 14.5kg
AY502-320W Medium Size
502*390*205 mm 465*365*110 mm 20.5 kg
AY502-400W Current
Large Capacity
502*390*270 mm 465*365*140 mm 23.5 kg

All dimensions are subject to a standard manufacturing tolerance of ±1mm. Custom CNC machining, powder coating, and hole drilling are available upon request.

How to Evaluate AY502-400W Heat Dissipation

The finned structure provides a heat-dissipation surface, but the enclosure’s thermal suitability cannot be determined from the model name or listed operating power alone. The actual heat load, component losses, ambient temperature, solar exposure, installation orientation, wall contact, internal layout and allowable internal temperature must be considered together.

01

Separate operating power from heat load

The listed operating power is 400–500W. This figure should not be treated as the heat released by the installed equipment. Confirm the actual electrical losses and total heat load before selecting the cooling arrangement.

02

Check the internal envelope

Compare the 465 × 365 × 140 mm internal space with the equipment dimensions, connector clearance, cable bend radius, insulation distance and service access requirements.

03

Keep the fins effective

Avoid covering the finned surfaces. Confirm whether the final orientation allows natural convection and whether nearby structures block the available heat-dissipation area.

04

Balance cooling and sealing

A sealed IP67 configuration can limit natural airflow. If the installed equipment needs assisted cooling, the fan, heat exchanger, thermal interface or external cooling arrangement must be designed together with the sealing strategy.

05

Validate the complete assembly

Final passive-cooling suitability should be confirmed through thermal calculation, prototype testing or simulation using the actual RF equipment, heat load and installation environment.

Send us the equipment heat load, ambient temperature range, installation orientation and internal component layout so we can review the enclosure configuration.

What to Confirm Before Choosing an RF Aluminum Housing for Counter-UAV Projects

Counter-UAV equipment may include different combinations of RF, communication, processing, control, power and interface modules. The enclosure should therefore be selected according to the installed equipment rather than the application name alone.

  • Internal module dimensions
  • Connector and cable clearance
  • Required cable entries
  • Mounting method
  • Heat load
  • Service access
  • Gasket and sealing arrangement
  • Power and grounding requirements
  • Environmental conditions
  • Required compliance testing

AY502-400W provides a mechanical housing platform. Detection, tracking, communication, mitigation and control functions are supplied by the installed equipment, not by the enclosure itself.

Plan RF Interfaces Around the Complete Assembly

AY502-400W RF equipment housing with internal installation space

RF equipment integration requires early planning for connectors, cable routing, mounting points, grounding, sealing and service access. Interface openings should be reviewed together with the internal component layout and the required environmental protection.

Aluminum construction alone does not guarantee RF shielding effectiveness. Shielding, grounding and EMC performance depend on the complete enclosure design, lid interface, gasket, apertures, connectors, bonding method and validation process.

Designed Around Counter-UAV Equipment Integration Requirements

Need a larger housing for multiple outdoor modules?

The defined internal space helps engineers evaluate RF, communication, control and power equipment before production.

Worried about heat from high-power electronics?

The finned structure provides a heat-dissipation surface for thermal planning. Final cooling suitability depends on the actual equipment and environment.

Need to fit connectors, cables and mounting hardware?

External interfaces, cable entry locations, mounting points and internal structure can be reviewed around the actual equipment layout.

Need to balance outdoor sealing and RF integration?

The enclosure configuration, sealing, grounding, connector layout and thermal design should be reviewed together before production.

Applications for AY502-400W

AY502-400W can be evaluated for the following outdoor equipment applications:

RF aluminum housing for Counter-UAV projects
Outdoor RF equipment housing
RF detection equipment
Communication and control modules
RF power amplifier assemblies
Telecom equipment
Surveillance and security electronics
Power and signal-processing equipment
Industrial electronic equipment
Outdoor communication systems
Custom large-format electronic assemblies

Application suitability depends on the installed equipment dimensions, actual heat load, mounting method, connector arrangement, environmental conditions and required compliance testing.

IP67 Enclosure Sealing Considerations

AY502-400W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample, so final IP67 suitability must be confirmed for the complete AY502-400W assembly, gasket condition, fasteners, cable glands and all customized openings.

An IP67 enclosure configuration depends on the complete assembled product. Any drilling, milling, connector installation, cable entry or interface modification must be reviewed for sealing performance before production.

AY502-400W finned aluminum enclosure

Custom Aluminum Heat Sink Enclosure Options

Foshan Anyiyao Electrical Equipment Co., Ltd. supports enclosure customization from requirement review to drawing confirmation, sample or pre-production review, production, inspection, packing and delivery.

  • Internal mounting structure
  • External interface openings
  • Cable entry locations
  • Pole or wall mounting points
  • Tapping and milling
  • Color options
  • Nameplate
  • Silk-screen marking
  • Laser marking

Share your equipment dimensions, heat load, connector layout, cable entry requirements, mounting method and estimated quantity. The engineering team can then review the enclosure configuration and confirm the manufacturability of the requested changes.

Aluminum Enclosure Manufacturer for Counter-UAV Equipment

Foshan Anyiyao Electrical Equipment Co., Ltd. provides outdoor enclosure design coordination, die-cast aluminum enclosure production, customization and inspection support for electronic equipment applications.

The company’s process can include requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, mass production, inspection, packing and delivery.

Outdoor aluminum enclosure customization
Die-cast aluminum production
Heat-dissipation enclosure design coordination
Internal structure and interface customization
Pole and wall mounting integration
Large-format equipment integration
Inspection before packing and delivery

Frequently Asked Questions

What is AY502-400W used for?
AY502-400W is a large-format die-cast aluminum housing for outdoor RF, communication, power and electronic equipment integration. It can be evaluated for RF modules and Counter-UAV project equipment.
What are the overall and internal dimensions?
The overall size is 502 × 390 × 305 mm. The internal size is 465 × 365 × 140 mm. Engineers should also check connector clearance, cable routing, mounting hardware and service access before final confirmation.
What is the listed operating power?
The product specification lists an operating power of 400–500W. This is not the same as the actual heat load. Thermal selection should be based on the electrical losses generated by the installed equipment.
Can AY502-400W be used as an RF Power Amplifier Housing?
It can be evaluated for RF power amplifier and related outdoor electronic assemblies. Final suitability depends on the installed equipment dimensions, heat load, interfaces, mounting and environmental requirements.
Does AY502-400W guarantee passive cooling?
No. The finned construction provides a heat-dissipation surface, but passive-cooling suitability must be confirmed using the actual heat load, ambient conditions, installation orientation and complete assembly.
Is AY502-400W independently tested for IP67?
AY502-400W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample. Final sealing performance must be confirmed for the complete AY502-400W assembly and customized openings.
Does the aluminum housing guarantee RF shielding?
No. RF shielding effectiveness depends on the complete enclosure design, lid interface, gasket, apertures, connectors, grounding and test method. Any RF or EMC requirement should be specified and validated separately.
What mounting options are available?
The AY502-400W product specification lists pole or wall mounting. The final mounting interface should be reviewed according to the equipment weight, installation position and project requirements.
Can the internal structure and interfaces be customized?
Yes. Internal structure, external interfaces, cable entries, color, tapping, milling, nameplates, silk-screen marking and laser marking can be reviewed according to the project requirements.
What information should I provide for a quotation?
Please provide the equipment dimensions, actual heat load, ambient temperature, installation location, mounting method, cable entry requirements, connector layout, required openings, surface finish and estimated quantity.

Ready to Evaluate AY502-400W for Your Project?

Send us your equipment layout, heat load and interface requirements to confirm the enclosure configuration.