AY502-400W RF Aluminum Housing for Counter-UAV Projects
A finned die-cast aluminum enclosure for outdoor RF, communication, power and electronic equipment integration, with large internal space, listed IP67 protection and configurable interfaces.
Please provide the installed equipment dimensions, heat load, connector layout, mounting method and required openings for enclosure evaluation.
AY502-400W Aluminum Heat Sink Enclosure
AY502-400W is a large-format aluminum heat sink enclosure designed for outdoor RF, communication, power and electronic equipment integration. Its finned die-cast aluminum structure provides an external heat-dissipation surface, while the defined internal cavity supports equipment layout, cable routing and service-clearance planning.
The enclosure can be evaluated for RF equipment, counter-UAV system modules, communication units, RF power amplifier assemblies, telecom equipment, surveillance electronics, control modules and outdoor power electronics.
Foshan Anyiyao Electrical Equipment Co., Ltd. can review the required internal structure, cable entries, mounting points, external interfaces and identification requirements before production.
Important Note: AY502-400W is a mechanical housing. It does not provide drone detection, tracking, RF jamming, GPS spoofing, interception, antenna performance or command-and-control functions by itself. Those functions depend on the equipment installed inside and the complete system design.
Compliance: Counter-UAV and RF equipment must be used only in applications authorized by the applicable laws and regulations in the installation location.
Finned Die-Cast Aluminum Construction
Engineered for outdoor equipment integration, balancing structural rigidity, installation space, and thermal management planning.
Large Finned Heat-Dissipation Structure
The external fins provide an expanded heat-dissipation surface for passive or assisted thermal-management planning.
Die-Cast Aluminum Enclosure
The die-cast aluminum body provides a rigid enclosure platform for RF, communication, power and control modules.
Large Internal Installation Space
The 465 × 365 × 140 mm internal space supports equipment layout, connector clearance, cable routing and service access planning.
Outdoor Equipment Protection
The product specification lists IP67 protection, while the complete sealing result depends on the assembled enclosure, gaskets, cable entries and customized openings.
Pole or Wall Mounting
The AY502-400W product specification lists pole or wall mounting as the installation method.
Custom Interface Configuration
Internal structure, external interfaces, color, tapping, milling, nameplates, silk screen and laser marking can be reviewed according to project requirements.
AY502-400W Specifications
Review the physical dimensions, materials, and listed parameters to evaluate the enclosure for your outdoor electronic equipment integration.
| Item | Specification |
|---|---|
| Model | AY502-400W |
| Product Type | RF Aluminum Housing for Counter-UAV Projects |
| Series | Power / 502 |
| Brand | AY |
| Material | Aluminum |
| Processing Method | Die-cast aluminum |
| Color | Silver Grey |
| Surface Treatment | Electrostatic spraying |
| Overall Size | 502 × 390 × 305 mm |
| Internal Size | 465 × 365 × 140 mm |
| Weight | 23.5 kg |
| Protection Level | IP67 model reference, subject to complete assembly confirmation |
| Impact Resistance | IK10 |
| Installation | Pole or wall mounting |
| Operating Temperature | -40 ± 3°C to +105 ± 2°C |
| Operating Humidity | ≤90% RH |
| Operating Voltage | AC100–AC250V |
| Listed Operating Power | 400–500W |
| Customizable Parameters | Color, internal structure, external interfaces, tapping, milling, nameplate, silk screen and laser marking |
| Manufacturer | Foshan Anyiyao Electrical Equipment Co., Ltd. |
* Note: "Operating Power 400–500W" is the listed operating power range in the product specification. The actual cooling requirement must be evaluated based on equipment losses, ambient temperature, and installation method.
AY502 Series Size Comparison
Need a different capacity? Compare the current AY502-400W with our other heavy-duty die-cast aluminum enclosures in the same series to find the perfect fit for your equipment.
| Model | Outer Dimensions (L×W×H) | Inner Dimensions (L×W×H) | Weight | Action |
|---|---|---|---|---|
|
AY502-220W
Compact Size
|
502*390*145 mm | 465*365*70 mm | 14.5kg | |
|
AY502-320W
Medium Size
|
502*390*205 mm | 465*365*110 mm | 20.5 kg | |
|
AY502-400W
Current
Large Capacity
|
502*390*270 mm | 465*365*140 mm | 23.5 kg |
All dimensions are subject to a standard manufacturing tolerance of ±1mm. Custom CNC machining, powder coating, and hole drilling are available upon request.
How to Evaluate AY502-400W Heat Dissipation
The finned structure provides a heat-dissipation surface, but the enclosure’s thermal suitability cannot be determined from the model name or listed operating power alone. The actual heat load, component losses, ambient temperature, solar exposure, installation orientation, wall contact, internal layout and allowable internal temperature must be considered together.
Separate operating power from heat load
The listed operating power is 400–500W. This figure should not be treated as the heat released by the installed equipment. Confirm the actual electrical losses and total heat load before selecting the cooling arrangement.
Check the internal envelope
Compare the 465 × 365 × 140 mm internal space with the equipment dimensions, connector clearance, cable bend radius, insulation distance and service access requirements.
Keep the fins effective
Avoid covering the finned surfaces. Confirm whether the final orientation allows natural convection and whether nearby structures block the available heat-dissipation area.
Balance cooling and sealing
A sealed IP67 configuration can limit natural airflow. If the installed equipment needs assisted cooling, the fan, heat exchanger, thermal interface or external cooling arrangement must be designed together with the sealing strategy.
Validate the complete assembly
Final passive-cooling suitability should be confirmed through thermal calculation, prototype testing or simulation using the actual RF equipment, heat load and installation environment.
Send us the equipment heat load, ambient temperature range, installation orientation and internal component layout so we can review the enclosure configuration.
What to Confirm Before Choosing an RF Aluminum Housing for Counter-UAV Projects
Counter-UAV equipment may include different combinations of RF, communication, processing, control, power and interface modules. The enclosure should therefore be selected according to the installed equipment rather than the application name alone.
- Internal module dimensions
- Connector and cable clearance
- Required cable entries
- Mounting method
- Heat load
- Service access
- Gasket and sealing arrangement
- Power and grounding requirements
- Environmental conditions
- Required compliance testing
AY502-400W provides a mechanical housing platform. Detection, tracking, communication, mitigation and control functions are supplied by the installed equipment, not by the enclosure itself.
Plan RF Interfaces Around the Complete Assembly
RF equipment integration requires early planning for connectors, cable routing, mounting points, grounding, sealing and service access. Interface openings should be reviewed together with the internal component layout and the required environmental protection.
Aluminum construction alone does not guarantee RF shielding effectiveness. Shielding, grounding and EMC performance depend on the complete enclosure design, lid interface, gasket, apertures, connectors, bonding method and validation process.
Designed Around Counter-UAV Equipment Integration Requirements
Need a larger housing for multiple outdoor modules?
The defined internal space helps engineers evaluate RF, communication, control and power equipment before production.
Worried about heat from high-power electronics?
The finned structure provides a heat-dissipation surface for thermal planning. Final cooling suitability depends on the actual equipment and environment.
Need to fit connectors, cables and mounting hardware?
External interfaces, cable entry locations, mounting points and internal structure can be reviewed around the actual equipment layout.
Need to balance outdoor sealing and RF integration?
The enclosure configuration, sealing, grounding, connector layout and thermal design should be reviewed together before production.
Applications for AY502-400W
AY502-400W can be evaluated for the following outdoor equipment applications:
Application suitability depends on the installed equipment dimensions, actual heat load, mounting method, connector arrangement, environmental conditions and required compliance testing.
IP67 Enclosure Sealing Considerations
AY502-400W is included in the model/type reference list of the company’s EN 60529 IP67 report. The report identifies AY321-30W as the tested sample, so final IP67 suitability must be confirmed for the complete AY502-400W assembly, gasket condition, fasteners, cable glands and all customized openings.
An IP67 enclosure configuration depends on the complete assembled product. Any drilling, milling, connector installation, cable entry or interface modification must be reviewed for sealing performance before production.
Custom Aluminum Heat Sink Enclosure Options
Foshan Anyiyao Electrical Equipment Co., Ltd. supports enclosure customization from requirement review to drawing confirmation, sample or pre-production review, production, inspection, packing and delivery.
- Internal mounting structure
- External interface openings
- Cable entry locations
- Pole or wall mounting points
- Tapping and milling
- Color options
- Nameplate
- Silk-screen marking
- Laser marking
Share your equipment dimensions, heat load, connector layout, cable entry requirements, mounting method and estimated quantity. The engineering team can then review the enclosure configuration and confirm the manufacturability of the requested changes.
Aluminum Enclosure Manufacturer for Counter-UAV Equipment
Foshan Anyiyao Electrical Equipment Co., Ltd. provides outdoor enclosure design coordination, die-cast aluminum enclosure production, customization and inspection support for electronic equipment applications.
The company’s process can include requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, mass production, inspection, packing and delivery.
Frequently Asked Questions
What is AY502-400W used for?
What are the overall and internal dimensions?
What is the listed operating power?
Can AY502-400W be used as an RF Power Amplifier Housing?
Does AY502-400W guarantee passive cooling?
Is AY502-400W independently tested for IP67?
Does the aluminum housing guarantee RF shielding?
What mounting options are available?
Can the internal structure and interfaces be customized?
What information should I provide for a quotation?
Ready to Evaluate AY502-400W for Your Project?
Send us your equipment layout, heat load and interface requirements to confirm the enclosure configuration.