AY315-60W aluminum enclosure for counter-drone equipment

AY315-60W Aluminum Enclosure for Counter-Drone Equipment

A compact finned aluminum enclosure for outdoor detection, communication, control and power equipment integration, with defined internal space and customizable interfaces.

315 × 223 × 133 mm overall size | 296 × 209 × 78 mm internal size | Compact finned enclosure

Please provide the installed equipment dimensions, heat load, connector layout, mounting method and required openings for enclosure evaluation.

AY315-60W Aluminum Heat Sink Enclosure

AY315-60W is a compact aluminum enclosure designed for counter-drone equipment integration and other outdoor electronic applications. Its finned structure provides an external heat-dissipation surface, while the defined internal cavity supports component placement, cable routing and service-clearance planning.

The enclosure can be evaluated for RF equipment, communication modules, control electronics, power units, surveillance equipment and other compact outdoor electronic assemblies.

Foshan Anyiyao Electrical Equipment Co., Ltd. can review the required internal structure, cable entries, mounting points, external interfaces and identification requirements before production.

Important Operational Notice

AY315-60W is a mechanical equipment housing. It does not provide drone detection, tracking, RF jamming, GPS spoofing, interception or command-and-control functions by itself. Those functions depend on the equipment installed inside and the complete system design.

Counter-UAS and RF equipment must be used only in applications authorized by the applicable laws and regulations in the installation location.

AY315-60W aluminum heat sink enclosure with external fins AY315-60W compact die-cast aluminum enclosure

Core Engineering Features

Designed to support compact outdoor equipment integration and thermal management planning.

Compact Finned Aluminum Structure

The external fins provide a heat-dissipation surface for passive or assisted thermal-management planning.

Die-Cast Aluminum Enclosure

The aluminum enclosure provides a rigid mechanical platform for detection, communication, control and power modules.

Defined Internal Installation Space

The 296 × 209 × 78 mm internal space helps engineers evaluate equipment dimensions, connector clearance and cable routing before quotation.

Outdoor Equipment Integration

The compact housing can be evaluated for outdoor electronic equipment that requires mechanical protection and planned heat dissipation.

Custom Interface Configuration

Internal structure, external interfaces, cable entries, tapping, milling and identification details can be reviewed according to project requirements.

AY315-60W Specifications

Model AY315-60W
Product Type Aluminum Enclosure for Counter-Drone Equipment
Construction Compact finned aluminum enclosure
Dimensions Overall: 315 × 223 × 133 mm
Internal: 296 × 209 × 78 mm
Reference Weight Approximately 6 kg, subject to final production configuration
Application Outdoor electronic equipment integration
Customization Internal structure, external interfaces, color, tapping, milling, nameplate, silk screen and laser marking
Manufacturer Foshan Anyiyao Electrical Equipment Co., Ltd.

Technical Specifications

Detailed dimensional and weight data for the AY315 series die-cast aluminium enclosures.

Model Number External Dimensions (mm) Internal Dimensions (mm) Weight (kg)
AY315-40W 315 × 223 × 85 296 × 209 × 50 4.4
AY315-60W 315 × 223 × 133 296 × 209 × 78 5.0

How to Evaluate AY315-60W Heat Dissipation

The finned structure provides a heat-dissipation surface, but enclosure suitability cannot be determined from the model name alone. The actual heat load, component losses, ambient temperature, solar exposure, installation orientation, wall contact, internal layout and allowable internal temperature must be considered together.

AY315-60W finned aluminum enclosure

Send us the equipment heat load, ambient temperature range, installation orientation and internal component layout so we can review the enclosure configuration.

Request a Quote →
1

Confirm the actual heat load

Calculate the heat released by the installed electronics rather than using the equipment’s input power as the only reference.

2

Check the internal envelope

Compare the 296 × 209 × 78 mm internal space with the equipment dimensions, connector clearance, cable bend radius and service access requirements.

3

Keep the fins effective

Avoid covering the finned surfaces. Confirm whether the final installation position allows natural convection and whether adjacent structures block the available heat-dissipation area.

4

Review sealing and cooling together

If the final outdoor assembly requires a sealed configuration, consider how the sealing arrangement affects natural airflow and assisted cooling options.

5

Validate the complete assembly

Final passive-cooling suitability should be confirmed through thermal calculation, prototype testing or simulation using the actual equipment, heat load and installation environment.

What to Confirm Before Choosing a Counter-Drone Equipment Enclosure

Counter-drone equipment may include different combinations of detection, communication, processing, control and power modules. The enclosure should therefore be selected according to the installed equipment rather than the application name alone.

  • Internal module dimensions
  • Connector and cable clearance
  • Required cable entries
  • Mounting method
  • Heat load
  • Service access
  • Sealing requirements
  • Power and grounding requirements
  • Environmental conditions
  • Required compliance testing

AY315-60W provides a mechanical housing platform. Detection, tracking, communication, mitigation and control functions are supplied by the installed equipment, not by the enclosure itself.

Designed Around Compact Outdoor Equipment Integration

Need a compact housing for outdoor electronics?

The defined internal space helps engineers evaluate smaller detection, communication, control and power modules before production.

Need to manage heat in a compact enclosure?

The finned structure provides a heat-dissipation surface for thermal planning. Final cooling suitability depends on the actual equipment and environment.

Need to fit connectors and cable entries?

External interfaces, cable entry locations, mounting points and internal structure can be reviewed around the actual equipment layout.

Need a custom housing for a developing Counter-UAV project?

The AY315-60W platform can be evaluated before production based on equipment dimensions, heat load, mounting method, openings and required quantity.

Applications for AY315-60W

AY315-60W can be evaluated for the following compact outdoor equipment applications:

Aluminum Enclosure for Counter-Drone Equipment
RF equipment housing
Communication equipment enclosure
Detection and signal-processing modules
Control and power electronics
Surveillance and security equipment
Outdoor communication equipment
Industrial electronic equipment
Compact telecom equipment
Custom outdoor electronic assemblies

Application suitability depends on the installed equipment dimensions, actual heat load, mounting method, connector arrangement, environmental conditions and required compliance testing.

AY315-60W enclosure for detection and communication equipment

Plan Interfaces Around the Complete Assembly

RF and communication equipment integration requires early planning for connectors, cable routing, mounting points, grounding, sealing and service access. Interface openings should be reviewed together with the internal component layout and required environmental protection.

Aluminum construction alone does not guarantee RF shielding effectiveness. Shielding, grounding and EMC performance depend on the complete enclosure design, lid interface, gasket, apertures, connectors, bonding method and validation process.

Custom Aluminum Heat Sink Housing Options

Foshan Anyiyao Electrical Equipment Co., Ltd. supports enclosure customization from requirement review to drawing confirmation, sample or pre-production review, production, inspection, packing and delivery.

  • Internal mounting structure
  • External interface openings
  • Cable entry locations
  • Mounting points
  • Tapping and milling
  • Color options
  • Nameplate
  • Silk-screen marking
  • Laser marking

Share your equipment dimensions, heat load, connector layout, cable entry requirements, mounting method and estimated quantity. The engineering team can then review the enclosure configuration and confirm the manufacturability of the requested changes.

Aluminum Enclosure Manufacturer for Compact Outdoor Equipment

Foshan Anyiyao Electrical Equipment Co., Ltd. provides outdoor enclosure design coordination, die-cast aluminum enclosure production, customization and inspection support for electronic equipment applications.

The company’s process can include requirement discussion, engineering evaluation, drawing confirmation, sample or pre-production review, mass production, inspection, packing and delivery.

Outdoor aluminum enclosure customization

Die-cast aluminum production

Heat-dissipation enclosure design coordination

Internal structure and interface customization

Compact equipment integration

Inspection before packing and delivery

Frequently Asked Questions

Technical and application queries regarding the AY315-60W passive cooling aluminum enclosure.

What is AY315-60W used for?
AY315-60W is a compact aluminum enclosure for integrating detection, communication, control, power and electronic modules. It can be evaluated for Counter-UAV equipment and other outdoor electronic systems.
What are the overall and internal dimensions?
The overall size is 315 × 223 × 133 mm. The internal size is 296 × 209 × 78 mm. Engineers should also check connector clearance, cable routing, mounting hardware and service access before final confirmation.
Is AY315-60W a complete Counter-UAV system?
No. AY315-60W is an equipment enclosure. It does not provide drone detection, tracking, communication, RF mitigation, interception or command-and-control functions.
Does AY315-60W guarantee passive cooling?
No. The finned construction provides a heat-dissipation surface, but passive-cooling suitability must be confirmed using the actual heat load, ambient conditions, installation orientation and complete assembly.
Is AY315-60W independently tested for IP67?
The company’s current EN 60529 report lists AY315-40W as a model reference, not AY315-60W. Any IP67 requirement for AY315-60W must therefore be reviewed and confirmed for the complete customized assembly before publication or production.
Can the internal structure and interfaces be customized?
Yes. Internal structure, external interfaces, cable entries, color, tapping, milling, nameplates, silk-screen marking and laser marking can be reviewed according to the project requirements.
What information should I provide for a quotation?
Please provide the equipment dimensions, actual heat load, ambient temperature, installation location, mounting method, cable entry requirements, connector layout, required openings, surface finish and estimated quantity.
Can the enclosure be used for RF equipment?
It can be evaluated as a mechanical housing for RF and communication equipment. RF performance, shielding effectiveness, grounding and EMC suitability must be specified and validated for the complete assembled system.

Request a Quote for AY315-60W

Please provide your project details below. Our engineering team will review your requirements for internal space, interfaces, mounting, sealing and heat-dissipation.

sales@aysolarbox.com +8618038893519

Project Specifications

Supported formats: PDF, JPG, PNG, STEP, IGES, STL, DWG (Max 20MB)

Please include the equipment layout or drawing if available. This helps us review internal space, interfaces, mounting, sealing and heat-dissipation requirements.