A finned ADC12 die-cast aluminum enclosure with defined internal space, listed IP67 protection, pole or wall mounting, and configurable interfaces for outdoor electronic equipment.
430 × 424 × 175 mm overall size | 387 × 352 × 95 mm internal size | 16.5 kg | 20–170W listed operating power
AY430-150W is a finned ADC12 die-cast aluminum enclosure for outdoor RF, communication and electronic equipment. Its integrated fin structure provides an enclosure-level heat-dissipation surface, while the defined internal cavity supports equipment layout, mounting, cable routing and interface planning.
With a listed overall size of 430 × 424 × 175 mm and an internal size of 387 × 352 × 95 mm, AY430-150W gives engineering teams a clear starting point for checking equipment fit, heat-source position and service clearance.
Detailed dimensional and technical parameters for the Power/430 series.
| Model | AY430-150W |
|---|---|
| Series | Power/430 |
| Overall Size | 430 × 424 × 175 mm |
| Internal Size | 387 × 352 × 95 mm |
| Weight | 16.5 kg |
| Material | ADC12 Aluminum |
| Processing Method | Die Cast Aluminum |
| Surface Treatment | Electrostatic Spraying |
| Standard Color | Silver |
| Listed Protection Level | IP67 |
| Impact Resistance | IK10 |
| Installation | Pole / Wall Mounting |
| Operating Temperature | -40±3°C to +105±2°C |
| Operating Humidity | ≤90% RH |
| Operating Voltage | AC100–AC250V |
| Operating Power | 20–170W |
| Customizable Options | Color, inner structure, external interface |
| Additional Processing | Tapping and milling |
| Marking Options | Nameplate, silk screen and laser |
Please confirm the equipment envelope, actual heat load, heat-source location, cable-entry layout, mounting method and final sealing requirements before ordering.
Selecting a heat dissipation enclosure starts with the actual heat generated inside the equipment, not only the nominal input power. Evaluating a die cast aluminum heat sink housing involves reviewing the installed component losses, maximum ambient temperature, solar exposure, available external surface, mounting orientation, wall contact and allowable internal temperature.
List the heat generated by each installed component and calculate the total thermal load that the enclosure must manage.
Compare the equipment envelope with the listed 387 × 352 × 95 mm internal size, including mounting hardware, cable routing and service clearance.
The integrated fins provide an external heat-dissipation surface. Their effectiveness depends on orientation, airflow, ambient conditions and whether any surface is blocked by a wall or mounting structure.
Use the enclosure as one part of the thermal design. Final validation should consider the equipment, thermal interface, ambient temperature, sealing method and any active or assisted cooling.
AY430-150W does not carry a guaranteed thermal-resistance or temperature-rise value on the product specification. Confirm the thermal performance of the final assembly before production.
A finned enclosure can support passive heat-dissipation planning, but passive cooling is not automatically suitable for every sealed high-power assembly. Higher protection levels, high ambient temperatures, direct sunlight and limited airflow can change the thermal result.
The AY430-150W specification lists IP67 protection. Any ventilation, fan, cable gland, connector, machined opening or mounting change must be reviewed together with the final sealing requirement to ensure the integrity of an aluminum enclosure with a listed IP67 protection level.
AY430-150W is specified for pole or wall mounting and provides a large enclosure format for outdoor electronic equipment. Review the mounting direction, bracket position, cable-entry side, service access and clearance around the cooling fins before installation.
The finned aluminum structure provides a defined external surface for heat-dissipation planning around the installed equipment.
AY430-150W has a listed operating power range of 20–170W, but final cooling selection should be based on actual internal heat generation, ambient temperature and equipment operating conditions.
The listed 387 × 352 × 95 mm internal size helps engineers check equipment fit, component spacing, mounting hardware and cable routing.
The product specification lists IP67 protection and an integrated finned surface. The final design must balance sealing, cable entries, mounting and heat dissipation.
The listed customization scope includes inner structure, external interface, tapping, milling, nameplate, silk-screen marking and laser marking.
AY430-150W can be evaluated for outdoor RF, communication, security, monitoring, IoT, digital television and power equipment that requires a structured aluminum housing and an enclosure-level heat-dissipation surface. Confirm the equipment layout, heat load, interfaces, mounting arrangement and environmental requirements before final selection.
Use AY430-150W as a starting platform for project-specific enclosure integration. Customization can be reviewed around the internal equipment layout, heat-source position, external interfaces, cable entries, mounting details, surface finish and product identification.
Share your equipment requirements
Provide heat-load and ambient-condition information
Review dimensions, interfaces and mounting details
Confirm drawings and customization requirements
Arrange sample or pre-production review when required
Proceed with production and quality inspection
Foshan Anyiyao Electrical Equipment Co., Ltd. focuses on outdoor enclosure development, production coordination, customization and quality control for communication, surveillance, CATV, power distribution and industrial electronic equipment.
For AY430-150W projects, buyers can provide equipment dimensions, component heat losses, ambient conditions, connector locations, mounting requirements, cable-entry details and surface-finish expectations for technical review.
The AY430-150W product specification lists an IP67 protection level, and the model is included in the company’s EN 60529 IP67 model reference list. Final performance depends on the complete assembled configuration and customized openings.
Please share your equipment dimensions, total heat load, main heat sources, maximum ambient temperature, mounting method, quantity and target application so we can review the AY430-150W configuration.