AY430-150W heat dissipation enclosure manufacturer product

AY430-150W Heat Dissipation Enclosure Manufacturer for Outdoor RF and Telecom Equipment

A finned ADC12 die-cast aluminum enclosure with defined internal space, listed IP67 protection, pole or wall mounting, and configurable interfaces for outdoor electronic equipment.

430 × 424 × 175 mm overall size 387 × 352 × 95 mm internal size 16.5 kg 20–170W listed operating power

AY430-150W Aluminum Heat Sink Enclosure

AY430-150W is a finned ADC12 die-cast aluminum enclosure for outdoor RF, communication and electronic equipment. Its integrated fin structure provides an enclosure-level heat-dissipation surface, while the defined internal cavity supports equipment layout, mounting, cable routing and interface planning.

With a listed overall size of 430 × 424 × 175 mm and an internal size of 387 × 352 × 95 mm, AY430-150W gives engineering teams a clear starting point for checking equipment fit, heat-source position and service clearance.

AY430-150W aluminum heat sink enclosure

AY430-150W Specifications

Detailed dimensional and technical parameters for the Power/430 series.

Model AY430-150W
Series Power/430
Overall Size 430 × 424 × 175 mm
Internal Size 387 × 352 × 95 mm
Weight 16.5 kg
Material ADC12 Aluminum
Processing Method Die Cast Aluminum
Surface Treatment Electrostatic Spraying
Standard Color Silver
Listed Protection Level IP67
Impact Resistance IK10
Installation Pole / Wall Mounting
Operating Temperature -40±3°C to +105±2°C
Operating Humidity ≤90% RH
Operating Voltage AC100–AC250V
Operating Power 20–170W
Customizable Options Color, inner structure, external interface
Additional Processing Tapping and milling
Marking Options Nameplate, silk screen and laser

Please confirm the equipment envelope, actual heat load, heat-source location, cable-entry layout, mounting method and final sealing requirements before ordering.

How to Evaluate AY430-150W Heat Dissipation

Selecting a heat dissipation enclosure starts with the actual heat generated inside the equipment, not only the nominal input power. Evaluating a die cast aluminum heat sink housing involves reviewing the installed component losses, maximum ambient temperature, solar exposure, available external surface, mounting orientation, wall contact and allowable internal temperature.

1

Confirm the Internal Heat Load

List the heat generated by each installed component and calculate the total thermal load that the enclosure must manage.

2

Check the Available Internal Space

Compare the equipment envelope with the listed 387 × 352 × 95 mm internal size, including mounting hardware, cable routing and service clearance.

3

Review the Finned Surface and Orientation

The integrated fins provide an external heat-dissipation surface. Their effectiveness depends on orientation, airflow, ambient conditions and whether any surface is blocked by a wall or mounting structure.

4

Confirm the Complete Thermal Design

Use the enclosure as one part of the thermal design. Final validation should consider the equipment, thermal interface, ambient temperature, sealing method and any active or assisted cooling.

AY430-150W does not carry a guaranteed thermal-resistance or temperature-rise value on the product specification. Confirm the thermal performance of the final assembly before production.

AY430-150W finned aluminum enclosure

Passive Cooling Aluminum Enclosure with IP Requirements

A finned enclosure can support passive heat-dissipation planning, but passive cooling is not automatically suitable for every sealed high-power assembly. Higher protection levels, high ambient temperatures, direct sunlight and limited airflow can change the thermal result.

The AY430-150W specification lists IP67 protection. Any ventilation, fan, cable gland, connector, machined opening or mounting change must be reviewed together with the final sealing requirement to ensure the integrity of an aluminum enclosure with a listed IP67 protection level.

  • Finned external surface
  • Listed IP67 protection level
  • Thermal validation based on the complete assembly

Outdoor Aluminum Enclosure for RF and Telecom Equipment

AY430-150W is specified for pole or wall mounting and provides a large enclosure format for outdoor electronic equipment. Review the mounting direction, bracket position, cable-entry side, service access and clearance around the cooling fins before installation.

Installation Checklist

  • Pole or wall mounting
  • Mounting bracket and fastener requirements
  • Cable-entry direction
  • Service and maintenance clearance
  • Clearance around finned surfaces
  • Final IP sealing after installation
AY430-150W IP67 outdoor aluminum enclosure

Designed Around Real Heat-Dissipation Requirements

Need more than a plain-wall enclosure?

The finned aluminum structure provides a defined external surface for heat-dissipation planning around the installed equipment.

Need to select an enclosure based on real heat load?

AY430-150W has a listed operating power range of 20–170W, but final cooling selection should be based on actual internal heat generation, ambient temperature and equipment operating conditions.

Need a larger internal layout area?

The listed 387 × 352 × 95 mm internal size helps engineers check equipment fit, component spacing, mounting hardware and cable routing.

Need IP protection and heat management together?

The product specification lists IP67 protection and an integrated finned surface. The final design must balance sealing, cable entries, mounting and heat dissipation.

Need customized equipment interfaces?

The listed customization scope includes inner structure, external interface, tapping, milling, nameplate, silk-screen marking and laser marking.

Typical Applications for AY430-150W

AY430-150W can be evaluated for outdoor RF, communication, security, monitoring, IoT, digital television and power equipment that requires a structured aluminum housing and an enclosure-level heat-dissipation surface. Confirm the equipment layout, heat load, interfaces, mounting arrangement and environmental requirements before final selection.

RF Power Amplifier Housing
Outdoor RF Amplifier Enclosure
Telecom Equipment Enclosure
Communication equipment
RF remote units
Repeaters
Video surveillance and IoT equipment
Digital TV relay equipment
Outdoor power supply equipment
Security and industrial electronics

Custom Aluminum Heat Sink Housing for Thermal Equipment Integration

Use AY430-150W as a starting platform for project-specific enclosure integration. Customization can be reviewed around the internal equipment layout, heat-source position, external interfaces, cable entries, mounting details, surface finish and product identification.

Inner structure
External interface
Cable-entry layout
Mounting details
Color and surface treatment
Tapping and milling
Nameplate
Silk-screen marking
Laser marking

Customization Process

  • 1

    Share your equipment requirements

  • 2

    Provide heat-load and ambient-condition information

  • 3

    Review dimensions, interfaces and mounting details

  • 4

    Confirm drawings and customization requirements

  • 5

    Arrange sample or pre-production review when required

  • 6

    Proceed with production and quality inspection

Work With an Aluminum Enclosure Manufacturer

Foshan Anyiyao Electrical Equipment Co., Ltd. focuses on outdoor enclosure development, production coordination, customization and quality control for communication, surveillance, CATV, power distribution and industrial electronic equipment.

For AY430-150W projects, buyers can provide equipment dimensions, component heat losses, ambient conditions, connector locations, mounting requirements, cable-entry details and surface-finish expectations for technical review.

The AY430-150W product specification lists an IP67 protection level, and the model is included in the company’s EN 60529 IP67 model reference list. Final performance depends on the complete assembled configuration and customized openings.

Foshan Anyiyao Electrical Equipment Co., Ltd. Logo

Manufacturer Capabilities

  • Product documentation and dimensional references
  • ADC12 die-cast aluminum enclosure capability
  • Project-based customization
  • Drawing and interface confirmation
  • Production and quality inspection coordination
  • EN 60529 IP67 documentation for the listed outdoor-aluminum-box model family

AY430-150W Heat Dissipation Enclosure FAQ

What is the internal size of AY430-150W?
The listed internal size is 387 × 352 × 95 mm. Confirm the equipment envelope, mounting hardware, cable routing and service clearance before ordering.
What is the overall size and weight?
The listed overall size is 430 × 424 × 175 mm, and the listed weight is 16.5 kg.
What operating power is listed for AY430-150W?
The listed operating power range is 20–170W. Actual cooling requirements depend on the heat generated by the installed equipment, ambient temperature and enclosure installation.
Does AY430-150W provide passive cooling?
The finned structure provides an external heat-dissipation surface that can support passive or assisted thermal-management planning. Final passive-cooling suitability must be validated for the complete assembly.
Can AY430-150W be used for RF amplifier equipment?
It can be evaluated as an RF Power Amplifier Housing or Outdoor RF Amplifier Enclosure when the equipment dimensions, heat load, interfaces and mounting requirements are compatible. The enclosure itself does not specify RF electrical performance.
Is AY430-150W an IP67 aluminum enclosure?
The product specification lists an IP67 protection level, and AY430-150W appears in the company’s EN 60529 IP67 model reference list. Confirm the final configuration and sealing requirements when custom openings or connectors are added.
Can the enclosure be customized?
Yes. Listed customization includes color, inner structure, external interface, tapping, milling, nameplate, silk-screen marking and laser marking.
What information is needed for thermal enclosure selection?
Provide the equipment dimensions, total heat load, component heat sources, maximum ambient temperature, mounting method, cable-entry layout, required quantity and target application.

Send Thermal Requirements

Please share your equipment dimensions, total heat load, main heat sources, maximum ambient temperature, mounting method, quantity and target application so we can review the AY430-150W configuration.

Technical Details